iquota

Fire safety in hotels, hostels, apartments and holiday rentals in Spain and Andalusia: what the rules require in 2026

Updated: 10 November 2026

Extinguishers, servicing, fire detection, evacuation plans, self-protection plans: what actually applies to you, depending on whether you run a hotel, a hostel, a tourist apartment or a holiday home? We read Spain's fire protection installations regulation (Royal Decree 513/2017, known as RIPCI), the fire safety section of the Technical Building Code (CTE DB-SI), the new Basic Self-Protection Directive published in the BOE in October 2026 and the Andalusian tourism rules (Decree-Law 13/2020, Decree 194/2010 and Decree 28/2016). Links are at the end. Where we could not confirm something, we say so. This is not technical or legal advice: for your building, ask an authorised fire protection maintenance company and the architect or engineer who signed, or will sign, your project.

The short answer

In November 2026, based on what we read:

Extinguishers and servicing (Royal Decree 513/2017, RIPCI)

The national regulation (BOE consolidated text, last amended 3 September 2025) says:

Hotels, hostels and apartments: the CTE DB-SI

The building code fire safety section applies when you design, refurbish or change use. What we read (2019 version):

Self-protection plans: what changed in October 2026

Order INT/1068/2026 (BOE, 10 October 2026) publishes the new Basic Self-Protection Directive, in force since 11 October:

Andalusia: self-protection

Andalusia: what the tourism rules require

On top of the above, which applies to everyone:

Quick checklist

How iQuota helps

We make your property available to AI assistants through a connector, with direct booking, payment at the property and 0% commission. Nobody can guarantee that an AI will recommend you.

Want an official booking page AI can read and a connector with your real prices, commission-free? The first 30 hotels join free until 30 June 2027.

See the Founding Hotels programme

Frequently asked questions

How often must extinguishers in a hotel or holiday home be checked?

Under annex II of Royal Decree 513/2017: every three months, a visual check by you or the maintenance company; every year, a service by an authorised maintenance company (UNE 23120); every five years, a pressure test, with a maximum of three re-tests.

Does a hotel need a self-protection plan in 2026?

Under Royal Decree 393/2007, yes from 28 m of evacuation height or 2,000 people. Since 11-10-2026 a new Basic Directive applies that has no specific entry for hotels, but authorities may be stricter. Ask your town hall and a specialist.

Is an extinguisher mandatory in a holiday home in Andalusia?

Yes. The annex to Decree 28/2016 requires an extinguisher, some type of smoke detector near the kitchen and a first-aid kit. As a home it is exempt from the RIPCI ten-yearly inspection (art. 22(2)), but the extinguisher must still be serviced.

Sources

More guides for hotels

More guides for hotels →

Español